欢迎来到中国电源学会电子资源平台
会员 A New Parallel Compensation Control Strategy of Power Factor Corrector without Electrolytic Capacitor by Power Decoupling
  • 7
  • 0
  • 0
  • 0
摘要
A new parallel compensation control strategy is proposed in this paper, which is applied to the power decoupled PFC without electrolytic capacitor and realizes the purpose of improving the service life and reliability of the system. In this paper, step-up bidirectional Buck/Boost converter is regarded as the power decoupling circuit firstly. The parallel compensation control strategy based on fixed duty cycle is proposed and its compensation characteristics are analyzed. And then a new type of parallel compensation control strategy is proposed on the basis of fixed duty ratio control strategy. Compared with the traditional control strategy, the new control strategy has simple structure, easy implementation, fast response speed, short system adjustment time, the load voltage ripple is not sensitive to changes in load power, and realizes sensorless and low cost power decoupling. Finally, the simulation and experimental study of the new parallel compensation control strategy are performed to verify the validity of the proposed scheme.
  • 若对本资源有异议或需修改,请通过“提交意见”功能联系我们,平台将及时处理!
来源
关键词
相关推荐