欢迎来到中国电源学会电子资源平台
会员 Research on Control Strategy of Phase Shifted Full Bridge Converter Based on Pulse Load Current Feedforward
  • 7
  • 0
  • 0
  • 0
摘要
In order to solve the problem of slow dynamic response of the system under the condition of pulse load, this paper takes the phase-shifted full-bridge converter as the research object, and proposes a constant voltage control strategy based on load current feedforward. Firstly, the open-loop equivalent impedance and closed-loop equivalent impedance of the system are analyzed through the small-signal model of the phase-shifted full-bridge converter, and the effect of closed-loop equivalent impedance on the constant voltage control is discussed. Then it is pointed out that reducing the closed-loop equivalent impedance of the system can reduce the disturbance of the output voltage caused by sudden load change. A feedforward control strategy of the load current is proposed and the feedforward controller is designed from the angle of reducing the closed-loop equivalent impedance. Finally, the simulation results show that the dynamic response speed of the system is improved significantly after the load current feedforward control is added, which can effectively suppress the disturbance of constant voltage output when the pulse load changes.
  • 若对本资源有异议或需修改,请通过“提交意见”功能联系我们,平台将及时处理!
来源
关键词
相关推荐
可试看前3页,请 登录 后进行更多操作
试看已结束,会员免费看完整版,请 登录会员账户 或申请成为中国电源学会会员.
关闭
温馨提示
确认退出登录吗?
温馨提示
温馨提示
温馨提示
确定点赞该资源吗?
温馨提示
确定取消该资源点赞吗?
温馨提示
确定收藏该资源吗?
温馨提示
确定取消该资源收藏吗?
温馨提示
确定加入购物车吗?
温馨提示
确定加入购物车吗?
温馨提示
确定移出购物车吗?