欢迎来到中国电源学会电子资源平台
会员 A Misalignment-Tolerant IPT Converter with Asymmetric Rectangular-Solenoid Coupler
  • 6
  • 0
  • 0
  • 0
  • 2023/01/01
  • 作者:
    Hai Xu  , Xiaohui Qu  , Zhicong Huang  
  • 页数:
    4
  • 页码:
    725 - 728
  • 资源:
  • 文件大小:
    1.23M
摘要
Inductive electric vehicle charging emerges as a promising technology by virtue of convenience and safety characteristics. However, IPT(Inductive Power Transfer) charger alignment tolerance is a critical issue in EV charging. In this paper, An IPT converter with asymmetric rectangular-solenoid (ARS) coupler is proposed to improve the misalignment-tolerant during the EV battery charging process. The ARS coupler combines a rectangular coil and a solenoid coil on the receiver side while the transmitter utilizes a rectangular coil. The coils arranged on the same side are spatially integrated and magnetically decoupled. Experimental verification of the proposed IPT converter with asymmetric rectangular-solenoid coupler is performed in a laboratory prototype with a 1 kW. And the result shows that the IPT system with ARS coupler can maintain a width range of misalignment.
  • 若对本资源有异议或需修改,请通过“提交意见”功能联系我们,平台将及时处理!